This Power Purchase agreement is entered into at on this 22 Day of December 2024 ,between Bangalore Electricity Supply Company Limited (BESCOM), a Government of Karnataka undertaking, being a Company formed and incorporated in India under the Companies Act-1956, with its registered office located at Bangalore, Karnataka State, represented by BESCOM AEE hereinafter referred to as the “BESCOM”, (which expression shall, unless repugnant to the context or meaning thereof, include its successors and permitted assigns), as party of the first part
the consumer of BESCOM residing at hereinafter, referred to as the "Seller" (which expression shall, unless repugnant to the context or meaning thereof, include his successors and permitted assigns) as party of the second part
Whereas,
a. The Seller intends to connect and operate the Solar Roof Top Photo Voltaic (SRTPV) system with BESCOM’s HT/LT Distribution system for sale of Solar Power to BESCOM, in terms of the " Karnataka Electricity Regulatory Commission’s (KERC) Order to be determined for the period from 01.04.2024 to 31.03.2025 ".
b. The Seller intends to install a SRTPV system of kWp capacity on the existing roof top of the premises, situated at and bearing RR. No in the same premises, under AEE of BESCOM
c. The Seller intends to sell the energy, generated from the SRTPV system to BESCOM on Gross metering basis, from the date of commissioning of the SRTPV system.
d. BESCOM intends to purchase the energy, generated by such SRTPV system, on Gross-metering basis, at the tariff determined by the KERC.
Now therefore, in consideration of the foregoing premises, the parties, hereto, intending to be legally bound, hereby agree as under:
1. Technical and Interconnection Requirements:
Seller shall ensure his SRTPV system complies with the following technical and interconnection requirement and shall:
1.1 Comply with the applicable standards and conditions, in respect of integrating the SRTPV system with the distribution system.
1.2 Connect and operate the SRTPV system to BESCOM’s distribution system, in accordance with the State Grid Code, and distribution Code as amended from time to time.
1.3 Install, prior to connection of SRTPV system to BESCOM’s distribution system, an inverter with an automatic inbuilt isolation device.
1.4 Provide external manual isolation mechanism with suitable locking facility, so that SRTPV system will not back-feed into the BESCOM’s network in case of power outage of the BESCOM’s distribution system, and it shall be accessible for BESCOM to operate, if required, during maintenance / emergency conditions.
1.5 Install all the equipment of SRTPV system compliant with relevant International (IEEE/IEC) and Indian standards (BIS).
1.6 (a) The SRTPV system shall be designed, engineered and constructed and operated by the Seller or any other person on his behalf, with reasonable diligence, subject to all applicable Indian Laws, Rules, Regulations as amended from time to time and orders having the force of law.
(b) The Seller, shall commission the SRTPV system, within six months from the date of approval of the PPA.
1.7 Adhere to the following power quality measures, as per the International and Indian standards and/or such other measures stipulated by KERC/BESCOM:
i) Harmonic current: Harmonic current injections from a generation unit shall not exceed the limits specified in IEEE 519.
ii) Voltage at the injection point should be in the operating range of 80% to 110% of the nominal connected voltage.
iii) Flicker: Operation of Photovoltaic system shouldn’t cause voltage flicker in excess of the limits stated in the relevant sections of IEC standards or other equivalent Indian standards, if any.
iv) Frequency: When the system frequency exceeds the upper limit, specified in the IEGC as amended from time to time, the SRTPV system shall shift to island mode.
v) DC Injection: Photovoltaic system should not inject DC power more than 0.5% of full rated output at the interconnection point or 1% of rated inverter output current into distribution system under any operating conditions.
vi) Power Factor: While the output of the inverter is greater than 50%, a lagging power factor of greater than 0.9, shall be maintained.
vii) The SRTPV system, in the event of voltage or frequency variations must island/disconnect itself, as per IEGC/KEGC Regulations, within the stipulated period.
2. Safety:
The Seller, shall comply with the following safety measures:
2.1 The Seller shall comply with the Central Electricity Authority (Measures Relating to Safety and Electricity Supply) Regulations, 2010.
2.2 The Seller shall ensure that, the design, installation, maintenance and operation of the SRTPV system, are in a manner conducive to the safety of the SRTPV system, as well as the BESCOM’s distribution system.
2.3 If the Seller’s SRTPV system either, causes damage to and/or produces adverse effects on the other consumer’s or BESCOM’s assets, Seller will disconnect SRTPV system immediately, from the distribution system, by himself or upon directions from the BESCOM and rectify the same at his own cost before reconnection.
3. Clearances and Approvals
The Seller shall obtain BESCOM’s and other statutory approvals and clearances before connecting the SRTPV system to the distribution system.
4. Access and Disconnection
4.1 BESCOM shall have access to metering equipment and disconnecting device of SRTPV system, both automatic and manual, at all times.
4.2 In emergency or outage situation, where there is no access to a disconnecting device either, automatic or manual, the BESCOM shall have the right to disconnect power supply to the premises.
5. Liabilities
The Seller, shall be solely responsible for availing any fiscal or other incentive provided by the State/ Central government, at his own expenses.
6. Commercial Settlement-
6.1 Tariff:
a. The BESCOM shall pay the tariff for the net energy/gross energy (as the case may be) at the tariff, that may be determined by the Commission for the period from 01.04.2024 to 31.03.2025 subject to such other conditions, if any, as may be imposed in the tariff order, for the term of the agreement.
b. If for any reason the date of commissioning is delayed, beyond the date of commissioning agreed. The tariff payable by the BESCOM shall be lower of the:
i) Tariff agreed to in this agreement
OR
ii) Any revised tariff, determined by the Commission, prevailing on the date of commissioning
OR
iii) 90% of the tariff agreed to in this agreement.
c. The import energy recorded in the bi-directional meter during a bill period shall be billed at higher of the
i) Tariff agreed to in this agreement.
OR
ii)Prevailing retail supply tariff applicable to the category of the installation of the seller
d.The Seller shall pay the electricity tax and other statutory levies pertaining to SRTPV generation, as may be levied from time to time.
e. The seller shall not have claim for compensation, if the solar power genearted by his SRTPV system could not be absorbed by the distribution system due to failure of power supply in the grid / distribution system due to to failure of power supply in the grid / distribution system for the reasons, such as line clear, load shedding and line faults, whatsoever.
7. Metering:
7.1 In addition to the existing meter, the seller install the Bi-directional meter (whole current/CT operated) at the point of interconnection to the distribution system, at a suitable place in the premises, accessible for recording export of energy, from the SRTPV system to the grid and import of energy to the premises of the consumer from the grid. The bi-directional meter, shall comply with the Central Electricity Authority (Installation and operation of meters) Regulations, 2006 and shall have the following features:
i. Separate registers, for recording export and import energy with facility to download by Meter Reading Instrument (MRI).
ii. kVA, kW and kVAR measuring registers for both import and export.
iii. The Meter shall have RS232 (or higher) communication optical port / Radio Frequency (RF) port to support Automatic Meter Reading (AMR).
8. BILLING AND PAYMENT:
8.1 BESCOM shall issue monthly electricity bill for the gross-energy exported on the scheduled date of meter reading.
8.2 BESCOM shall pay for the gross energy exported as per the tariff agreed in this agreement within 30 days of issue of bill.
8.3 The import of energy recorded in the bi-directional meter during the billing period, shall be billed as per the clause 6.1 of this agreement and shall be deducted out of the amount payable towards gross energy exported.
8.4 The BESCOM shall pay interest at the rate of 0.75% per month, in case of any delay in payment beyond 30 (thirty) days period from the date of issue of bill, for the Gross-energy exported.
8.5 The seller shall continue to pay the charges for the consumption of electricity to his premises as per the retail tariff bill issued to him as required.
9. Term and Termination of the Agreement
9.1 This agreement shall be in force for a period of 25 years from the date of commissioning of the SRTPV system, unless terminated otherwise, as provided here under.
9.2 If the BESCOM commits any breach of the terms of the Agreement, Seller shall serve a written notice specifying the breach and calling upon the BESCOM to remedy/ rectify the same, within 30 (thirty) days or at such other period and at the expiry of 30 (Thirty) days or such other period from the delivery of the notice, Seller may terminate the agreement by delivering the termination notice, if the BESCOM fails to remedy/ rectify the same.
9.3 If the Seller commits any breach of the terms of the Agreement, BESCOM shall serve a written notice specifying the breach and calling upon the Seller to remedy/ rectify the same within 30 (thirty) days or at such other period and at the expiry of 30 (Thirty) days or such other period from the delivery of the notice, the BESCOM may terminate the agreement by delivering the termination notice, if the Seller fails to remedy/ rectify the same.
9.4 Upon termination of this Agreement, Seller shall cease to supply power to the distribution system and any injection of power shall not be paid for by the BESCOM.
10. Dispute Resolution:
All the disputes between the parties arising out of or in connection with this agreement shall be first tried to be settled through mutual negotiation.
The parties shall resolve the dispute in good faith and in equitable manner.
In case of failure to resolve the dispute, either of the parties may approach the appropriate Forum.
This Power Purchase agreement is entered into at on this 22 Day of December 2024 , between Bangalore Electricity Supply Company Limited (BESCOM), a Government of Karnataka undertaking, being a Company formed and incorporated in India under the Companies Act-1956, with its registered office located at Bangalore, Karnataka State, represented by BESCOM AEE hereinafter referred to as the “BESCOM”, (which expression shall, unless repugnant to the context or meaning thereof, include its successors and permitted assigns), as party of the first part
the consumer of BESCOM residing at hereinafter, referred to as the "Seller" (which expression shall, unless repugnant to the context or meaning thereof, include his successors and permitted assigns) as party of the second part
Whereas,
a. The Seller intends to connect and operate the Solar Roof Top Photo Voltaic (SRTPV) system with BESCOM’s HT/LT Distribution system for sale of Solar Power to BESCOM, in terms of the " Karnataka Electricity Regulatory Commission’s (KERC) Order to be determined for the period from 01.04.2024 to 31.03.2025 ".
b. The Seller intends to install a SRTPV system of kWp capacity on the existing roof top of the premises, situated at and bearing RR. No in the same premises, under AEE of BESCOM
c. The Seller intends to sell the energy, generated from the SRTPV system to BESCOM on Net metering basis, from the date of commissioning of the SRTPV system.
d. BESCOM intends to purchase the energy, generated by such SRTPV system, on Net-metering basis, at the tariff determined by the KERC.
Now therefore, in consideration of the foregoing premises, the parties, hereto, intending to be legally bound, hereby agree as under:
1. Technical and Interconnection Requirements:
Seller shall ensure his SRTPV system complies with the following technical and interconnection requirement and shall:
1.1 Comply with the applicable standards and conditions, in respect of integrating the SRTPV system with the distribution system.
1.2 Connect and operate the SRTPV system to BESCOM’s distribution system, in accordance with the State Grid Code, and distribution Code as amended from time to time.
1.3 Install, prior to connection of SRTPV system to BESCOM’s distribution system, an inverter with an automatic inbuilt isolation device.
1.4 Provide external manual isolation mechanism with suitable locking facility, so that SRTPV system will not back-feed into the BESCOM’s network in case of power outage of the BESCOM’s distribution system, and it shall be accessible for BESCOM to operate, if required, during maintenance / emergency conditions.
1.5 Install all the equipment of SRTPV system compliant with relevant International (IEEE/IEC) and Indian standards (BIS).
1.6 (a) The SRTPV system shall be designed, engineered and constructed and operated by the Seller or any other person on his behalf, with reasonable diligence, subject to all applicable Indian Laws, Rules, Regulations as amended from time to time and orders having the force of law.
(b) The Seller, shall commission the SRTPV system, within six months from the date of approval of the PPA.
1.7 Adhere to the following power quality measures, as per the International and Indian standards and/or such other measures stipulated by KERC/BESCOM:
i) Harmonic current: Harmonic current injections from a generation unit shall not exceed the limits specified in IEEE 519.
ii) Voltage at the injection point should be in the operating range of 80% to 110% of the nominal connected voltage.
iii) Flicker: Operation of Photovoltaic system shouldn’t cause voltage flicker in excess of the limits stated in the relevant sections of IEC standards or other equivalent Indian standards, if any.
iv) Frequency: When the system frequency exceeds the upper limit, specified in the IEGC as amended from time to time, the SRTPV system shall shift to island mode.
v) DC Injection: Photovoltaic system should not inject DC power more than 0.5% of full rated output at the interconnection point or 1% of rated inverter output current into distribution system under any operating conditions.
vi) Power Factor: While the output of the inverter is greater than 50%, a lagging power factor of greater than 0.9, shall be maintained.
vii) The SRTPV system, in the event of voltage or frequency variations must island/disconnect itself, as per IEGC/KEGC Regulations, within the stipulated period.
2. Safety:
The Seller, shall comply with the following safety measures:
2.1 The Seller shall comply with the Central Electricity Authority (Measures Relating to Safety and Electricity Supply) Regulations, 2010.
2.2 The Seller shall ensure that, the design, installation, maintenance and operation of the SRTPV system, are in a manner conducive to the safety of the SRTPV system, as well as the BESCOM’s distribution system.
2.3 If the Seller’s SRTPV system either, causes damage to and/or produces adverse effects on the other consumer’s or BESCOM’s assets, Seller will disconnect SRTPV system immediately, from the distribution system, by himself or upon directions from the BESCOM and rectify the same at his own cost before reconnection.
3. Clearances and Approvals
The Seller shall obtain BESCOM’s and other statutory approvals and clearances before connecting the SRTPV system to the distribution system.
4. Access and Disconnection
4.1 BESCOM shall have access to metering equipment and disconnecting device of SRTPV system, both automatic and manual, at all times.
4.2 In emergency or outage situation, where there is no access to a disconnecting device either, automatic or manual, the BESCOM shall have the right to disconnect power supply to the premises.
5. Liabilities
The Seller, shall be solely responsible for availing any fiscal or other incentive provided by the State/ Central government, at his own expenses.
6. Commercial Settlement-
6.1 Tariff:
a. The BESCOM shall pay the tariff for the net energy/gross energy (as the case may be) at the tariff, that may be determined by the Commission for the period from 01.04.2024 to 31.03.2025 subject to such other conditions, if any, as may be imposed in the tariff order, for the term of the agreement.
b. If for any reason the date of commissioning is delayed, beyond the date of commissioning agreed. The tariff payable by the BESCOM shall be lower of the:
i) Tariff agreed to in this agreement
OR
ii) Any revised tariff, determined by the Commission, prevailing on the date of commissioning
OR
iii) 90% of the tariff agreed to in this agreement.
c. The Seller, shall pay the Electricity tax and other statutory levies, pertaining to SRTPV generation, as may be levied from time to time.
d. The Seller shall not have any claim for compensation, if the Solar power generated by his SRTPV system could not be absorbed by the distribution system due to failure of power supply in the grid/ distribution system for the reasons, such as line clear, load shedding and line faults, whatsoever.
7. Metering:
7.1 The Seller, shall arrange to shift the existing meter to the generation side of SRTPV plant to measure solar power generation and install Bi-directional meter (whole current/CT operated) at the point of interconnection to the distribution system, at a suitable place in the premises, accessible for recording export of energy, from the SRTPV system to the grid and import of energy to the premises of the consumer from the grid. The bi-directional meter, shall comply with the Central Electricity Authority (Installation and operation of meters) Regulations, 2006 and shall have the following features:
i. Separate registers, for recording export and import energy with facility to download by Meter Reading Instrument (MRI).
ii. kVA, kW and kVAR measuring registers for both import and export.
iii. The Meter shall have RS232 (or higher) communication optical port / Radio Frequency (RF) port to support Automatic Meter Reading (AMR).
8. BILLING AND PAYMENT:
8.1 BESCOM shall issue monthly electricity bill for the net energy on the scheduled date of meter reading.
8.2 In case the exported energy is more than the imported energy BESCOM shall pay for the net energy exported, as per the Tariff agreed in this agreement, within 30 days from the date of issue of bill, duly adjusting the fixed charges and electricity duty, if any.
8.3 In case, the exported energy is less than the imported energy, the Seller shall pay BESCOM for the Net energy imported as per the prevailing retail supply tariff, determined by the Commission from time to time.
8.4 The BESCOM shall pay interest at the same rates, as is being levied on the consumers, for late payment charges, in case of any delay in payment beyond 30 (thirty) days period from the date of issue of bill, for the Net energy exported.
Explanation: Net metered energy means the difference of meter readings of energy injected by the SRTPV system into the grid (export) and the energy drawn from the grid for use by the Seller (import,) recorded in the bi-directional meter.
9. Term and Termination of the Agreement
9.1 This agreement shall be in force for a period of 25 years from the date of commissioning of the SRTPV system, unless terminated otherwise, as provided here under.
9.2 If the BESCOM commits any breach of the terms of the Agreement, Seller shall serve a written notice specifying the breach and calling upon the BESCOM to remedy/ rectify the same, within 30 (thirty) days or at such other period and at the expiry of 30 (Thirty) days or such other period from the delivery of the notice, Seller may terminate the agreement by delivering the termination notice, if the BESCOM fails to remedy/ rectify the same.
9.3 If the Seller commits any breach of the terms of the Agreement, BESCOM shall serve a written notice specifying the breach and calling upon the Seller to remedy/ rectify the same within 30 (thirty) days or at such other period and at the expiry of 30 (Thirty) days or such other period from the delivery of the notice, the BESCOM may terminate the agreement by delivering the termination notice, if the Seller fails to remedy/ rectify the same.
9.4 Upon termination of this Agreement, Seller shall cease to supply power to the distribution system and any injection of power shall not be paid for by the BESCOM.
10. Dispute Resolution:
All the disputes between the parties arising out of or in connection with this agreement shall be first tried to be settled through mutual negotiation.
The parties shall resolve the dispute in good faith and in equitable manner.
In case of failure to resolve the dispute, either of the parties may approach the appropriate Forum.
Account Id submitted in MNRE NAPS portal is Invalid or not Active.
Sending for Correction in MNRE NAPS Portal. Enter valid Account ID and Resubmit.
Note: Please refer Electricity bill for valid Account Id
Proposed Solar Capacity kW cannot exceed Sanctioned Load .
Sending for Correction in MNRE NAPS Portal.
Note:- Please enter complete Registration Reference Code Eg. NP/Reg-1234/2024 or R-KABE24-123456
FAST TRACK Load Enhancement Click Here
Account ID/Consumer ID: | |
Applicant Name: | |
Applicant Address: | |
Subdivision code: | |
Subdivision Name: | |
RR Number: | |
Sanctioned Load / Contract demand: | |
Connection Type: | |
Tariff category: |
@ 2020 - Design By BESCOM